The Welch Allyn HScribe Holter Analysis System includes:
- Current software CD.
- User Manual CD.
- CF Card Reader.
- H3+ USB Interface Cable.
- US Power Cord.
Warranty: 13 Months.
The Welch Allyn HScribe Holter Analysis System is intended to acquire, automatically analyze, edit, review, report, and store pre-recorded ECG data of patients that have been connected to compatible recorders. The cardiac data and analysis provided by HScribe is reviewed, confirmed, and used by trained medical personnel in the diagnosis of patients with various cardiac rhythm patterns.
The HScribe System eliminates the physical constraints of traditional Holter systems. No longer is the patient or recorder needed at your site. Instead, perform recorder hookup and download at your office, clinic, or hospital and simply transfer the recordings over a secure internet or intranet connection.
The HScribe database maintains centralized patient demographics and provides a repository for final reports, allowing clinicians to quickly search for patient information or a specific Holter record. Management of HScribe system settings includes password-protected user permissions, application settings, audit trails for regulatory compliance, and electronic signature, all of which are customizable based on facility preference. Save time and reduce costs by sharing and expediting Holter study workflow and results between networked locations with bidirectional connectivity via industry-standard DICOM or HL7 exchange.
Features
Welch Allyn HScribe Holter Analysis System Features
- Continuous 12-lead Holter analysis system configured for clinical research.
- Integrates with Surveyor systems for complete Holter analysis and ECG export.
- Export ECG waveform in XML format (FDA required) for selected time points.
- Identify subject data by protocol with database on PC or redundant server.
- Multiple workstations can acquire, review, and generate reports within a shared DB.
- Export 10-second, 12-lead ECG data to E-Scribe system for further analysis.
Specifications
Welch Allyn HScribe Holter Analysis System Specifications
-
Workstation Minimum Specifications:
-
Processor: Performance equivalent to an Intel Core i3.
-
Graphics: 1280 x 1024 (1920 x 1080 recommended).
-
RAM: 4 GB.
-
Operating System: Microsoft Windows 7 Professional 32-bit or 64-bit; Microsoft Windows 8.1 Professional 64 bit; Microsoft Windows 10 Pro 64 bit.
-
Hard Drive Capacity: 160 GB.
-
Archive: Network or external USB drive.
-
Input Devices: USB Standard keyboard and 2-button scroll mouse.
-
Software Installation: CD-ROM.
-
Network: 100 Mbps connection or better.
-
Printing Devices:
- HP M604n Laser printer (tested).
- HP PCL5-compatible printer series (recommended).
-
USB Ports: 2 free USB 2.0 ports.
-
Server Minimum Specifications:
-
Processor: Performance Equivalent to Intel Xeon class, Quad-Core with hyper-threading.
-
Graphics: 1024 x 768.
-
RAM: 4 GB.
-
Operating System: Microsoft Windows 2008 or 2012 server R2, 64-bit.
-
System Disk: 100 GB for OS and product installation (RAID recommended for data redundancy).
-
Data Disks:
- 550 GB hard drive space available.
- HD controller with 128 MB read/write cache (RAID recommended for data redundancy).
-
Archive: Network or external USB drive.
-
Software Installation: CD-ROM.
-
Network: 100 Mbps connection or better.
-
Input Devices: Standard keyboard and mouse.
-
Connectivity Interfaces:
-
Orders:
-
XML:
- Mortara XML.
- Accepts orders via XML files saved by external system in a shared folder.
-
DICOM Modality Worklist: Able to retrieve Holter test orders from a DICOM Service Class Provider (SCP) by performing a DICOM Modality Worklist query.
-
HL7: By adding optional Mortara HL7 Gateway.
-
DICOM Modality Worklist Query Parameters:
- Modality.
- Institution Name.
- Scheduled Station Name.
- Scheduled Procedure Step Location.
- Current Patient Location.
- Requested Procedure Location.
- Scheduled Procedure Step Description.
- Scheduled Station AE Title.
- Number of Days Before and After "Today".
- Requested Procedure Description.
-
Export Formats Supports exporting data in the following formats:
- PDF.
- XML.
- DICOM.
-
HL7: By adding optional Mortara HL7 Gateway.
-
Physical Characteristics:
-
Operating Temperature: +10 degrees C to +35 degrees C (+50 degrees F to +95 degrees F).
-
Storage Temperature: -40 degrees to +65 degrees C (-40 degrees to +149 degrees F).
-
Operating/Storage Humidity: 8% to 80%, non-condensing.
-
Altitude (Pressure): 3,000 meters.
Configurations
Welch Allyn HScribe Holter Analysis System Configurations
All variants include Version 6 with adult and pediatric arrhythmia analysis. Includes current software CD, user manual CD, CF card reader, H3+ USB interface cable, and US Power Cord
-
#HSCRIBE-6AA-AAXXB: Software Package Only.
-
#HSCRIBE-6AA-AXXXB: Software Package with Color LCD 24" monitor with 1920 x 1080 resolution, Report Export + DICOM bidirectional Interface; No printer.
-
#HSCRIBE-6AC-AXXXC: Software Package with Color LCD 24" monitor with 1920 x 1080 resolution, Report Export + DICOM bidirectional Interface, HP LaserJet 110V printer.
Literature
Welch Allyn HScribe Holter Analysis System Literature
Welch Allyn HScribe Holter Analysis System User Manual
Welch Allyn Cardiopulmonary Screening and Diagnosis Solutions Brochure
Welch Allyn HScribe Technical System Requirements
Welch Allyn HScribe Holter Analysis System Specifications
Welch Allyn HScribe Holter Analysis System Brochure
Customer Reviews 0 out of 5 - (Total 0 ratings)