The ValleyLab Force 2 Electrosurgical Generator includes a power cable. It is in excellent condition and certified to proper operating specifications.
Warranty: 90 Days - Parts and Labor.
High performance capabilities in a multipurpose electrosurgical generator. Blended Cut Modes provide flexibility through varying degrees of hemostasis. Choose one of three preset modes.
Simultaneous Independent Coagulation: Permits two surgeons to fulgurate from a single generator, for added convenience and efficacy. Accessories are activated only when keyed, reducing the potential for injury caused by inadvertent activation.
Low Voltage Coagulation: Ensures controlled, precise desiccation with less destruction of peripheral tissue, making the ValleyLab Force 2 electrosurgical generator ideal for laparoscopic procedures.
REM Safety: Guaranteed with ValleyLab's patented adaptive REM system, which continually monitors patient impedance levels. If a fault in the patient/return electrode contact is detected, the REM system automatically deactivates the generator - virtually eliminating the risk of burns under the return electrode. ValleyLab REM safety has been proven in more than 100 million surgical procedures worldwide.
Compatible with ValleyLab E6019 Bipolar Dome Footswitch and E6008B Monopolar Footswitch.
Features
ValleyLab Force 2 Electrosurgical Generator Features
-
Blended Cut Modes: Provide flexibility through varying degrees of hemostasis. Choose one of three preset modes.
-
Simultaneous Independent Coagulation: Permits two surgeons to fulgurate from a single generator, for added convenience and efficacy. Accessories are activated only when keyed, reducing the potential for injury caused by inadvertent activation.
-
Low Voltage Coagulation: Ensures controlled, precise desiccation with less destruction of peripheral tissue, making the ValleyLab Force 2 electrosurgical generator ideal for laparoscopic procedures.
-
REM Safety: Guaranteed with ValleyLab's patented adaptive REM system, which continually monitors patient impedance levels. If a fault in the patient/return electrode contact is detected, the REM system automatically deactivates the generator - virtually eliminating the risk of burns under the return electrode. ValleyLab REM safety has been proven in more than 100 million surgical procedures worldwide.
Specifications
ValleyLab Force 2 Electrosurgical Generator Specifications
- ValleyLab Footswitch Compatibility:
- #E6019 - Bipolar Dome Footswitch.
- #E6008B - Monopolar Footswitch.
-
Weight: 22 lb (10 kg).
Literature
ValleyLab Force 2 Electrosurgical Generator Literature
ValleyLab Force 2 Brochure
Valleylab Force 2 Electrosurgical Generator User Manual
Valleylab Force 2 Electrosurgical Generator Service Manual
Customer Reviews 0 out of 5 - (Total 0 ratings)