The reconditioned OEC 9900 Elite select configurations are ideal for Office,Outpatient and Ambulatory Center settings.
Superb Imaging
ÔÇó 1k x 1k x 16 bit resolution imaging
ÔÇó Advanced image processing accentuates what needs to be seen and attenuates what isnÔÇÖt needed
ÔÇó Dynamic Range Management technology processes images such as bone and vasculature separately for
optimum definition
ÔÇó Dose management options for more control: Digital Spot,High Level Fluoroscopy, Standard Fluoroscopy, Low Dose, and Pulse Mode
ÔÇó Smart Metal for enhanced imaging when metal is present
ÔÇó AutoTrak sampling window automatically moves with the anatomy to ensure superb images during live fluoro
Workflow Efficiency
ÔÇó Simple user interface with touchscreen reduces procedure time to improve efficiency
ÔÇó Flat panel monitors on an articulating arm allow viewing of images from anywhere in the room
ÔÇó Superb mechanical C-arm design features counterbalancing and friction controls for easier AP and
lateral movement, orbital rotation, and head-to-toe angulation
Refurbishing Process:
All OEC-9800ÔÇÖs go through a multistep refurbishing process. Each unit is restored to a like-new status. Pain Management, Orthopedics and Rehabilitation Services are just a few of the applications utilizing the refurbished OEC-9800 c-arm. The rotating x-ray tube allows for greater penetration and resolution for the lumbar area when doing needle localizations or other work involving the thicker anatomical areas of patients. For barium swallows a VCR or Digital Video Recorder can be utilized for better record keeping and post study analysis. The 1K X 1K CCD Technology used in the OEC-9800 image system allows for crisp, clear imaging. Whatever the purpose, a refurbished OEC-9800 will deliver the results you can depend on.
Mechanical repairs/cosmetic maintenance
ÔÇó All defective parts and covers are┬árepaired or replaced
ÔÇó C-arm is completely disassembled┬áand repainted
ÔÇó ÔÇ£CÔÇØ is removed from main frame┬áassembly
ÔÇó Horizontal arm removed, inspected┬áand repaired as necessary
ÔÇó Vertical column removed and┬ábearings removed inspected and┬áreplaced as required
ÔÇó X-ray tube removed and inspected┬áfor artifacts and internal integrity
ÔÇó Image intensifier removed and┬áinspected for any imperfections┬áand grid integrity
ÔÇó Camera removed
ÔÇó Wheels removed, cleaned and or┬áreplaced from main chassis
ÔÇó Chassis inspected for structural┬ádefects and repaired as necessary
ÔÇó Vertical lift assembly is tested for┬ádrift and adjusted/replaced if┬ánecessary
ÔÇó All bearings are inspected, cleaned┬áand re-lubricated, or replaced as┬áneeded
ÔÇó Control panel display is tested and┬áreplaced if necessary
ÔÇó All wheels are inspected and┬álubricated and/or replaced as┬áneeded, with new cable pushers┬áinstalled
ÔÇó All locks and brake assemblies are┬áinspected, cleaned, and repaired┬áor replaced as needed
ÔÇó C-arm is completely disassembled┬áand repainted
ÔÇó Steering is tested and adjusted is┬árequired
ÔÇó Foot switch and hand switch┬áprovided on each unit
ÔÇó A complete set of operator and┬áservice manuals are provided
Re-assembly
ÔÇó All components sent to C-arm┬áreassembly area for rebuilding
ÔÇó ÔÇ£CÔÇØ, Image tube and camera,┬áVertical column, main control and┬ápower cable installed
ÔÇó New batteries are installed
ÔÇó New CRT monitors installed in┬ámonitor cart
ÔÇó Monitor cart rebuilt
ÔÇó When C-arm is completely rebuilt┬ámechanically system is sent for┬ácalibration and final testing
Testing/calibration
ÔÇó Image intensifier and X-ray tube are tested for stability and balance
ÔÇó Image intensifier is tested for┬áresolution and gain to be within┬áOEM specifications
ÔÇó X-ray tube bearings are tested for┬ánoise and coast time
ÔÇó X-ray tube filaments and stator┬áwindings are tested
ÔÇó X-ray tube radiation output is┬áverified to be within OEM┬áspecifications
ÔÇó X-ray generator high voltage tested
ÔÇó Maximum dose rate is set in compliance with government┬áregulations
ÔÇó CCD camera calibrated to OEM┬áspecifications
ÔÇó X-ray beam is aligned for each field size
ÔÇó C-arm is tested for current leakage┬árequirements
ÔÇó All monitors are aligned, resized,┬ácentered and focused
ÔÇó All monitors are adjusted for┬ábrightness and linearity
ÔÇó Video system is optimized for gray┬áscale and resolution
ÔÇó All power supplies are tested and calibrated or replaced as┬ánecessary