The GE B125 Patient Monitor includes NIBP, IBP, Temperature, printer, 3 and 5 lead ECG, extension rack and battery, as well as your choice of SpO2.
Warranty:
-
Certified Refurbished: 90 Days.
-
Factory New: 1 Year.
The GE B125 Patient Monitor is a portable multi-parameter unit designed to be used for monitoring, recording, and to generate alarms for multiple physiological parameters of adult, pediatric, and neonatal patients in a hospital environment and during intra-hospital transport.
The B125 Patient Monitor is able to detect and generate alarms for the following ECG arrhythmias: Asystole, Ventricular tachycardia, VT>2, Ventricular Bradycardia, Accelerated Ventricular Rhythm, Ventricular Couplet, Bigeminy, Trigeminy, ÔÇ£R on TÔÇØ, Tachycardia, Bradycardia, Pause, Atrial Fibrillation, Multifocal PVCs, Missing Beat, Premature Ventricular Contraction (PVC) and Ventricular fibrillation.
Features
GE B125 Patient Monitor Features
- Seven pre-configured workflow settings for simple set-up.
- Auto-snapshot of most critical alarms.
- Alarm reporting options for better alarm management and instant care in cases of arrhythmia, high/low blood pressure, and ECG-lead detachment.
- Convenient screen lock button for easy cleaning, maintenance, and intra-hospital transport.
- Capacitive touchscreen for fast response and enhanced user experience.
- Uninterrupted display of primary ECG-lead waveform and other vital signs across settings.
- Choice of numerical or continuous waveform monitoring.
- Large numeric mode that enables critical parameter visibility even up to four meters.
Specifications
GE B125 Patient Monitor Specifications
-
Weight: 25 lb (11.3 kg).
-
Dimensions: 18" x 18" x 18" (45.7 cm x 45.7 cm x 45.7 cm).
-
Display:
-
Size: 12.1" (diagonal).
-
Resolution: 1280 x 800 pixels (WVGA).
-
Number of Waveforms: Up to 6.
-
Display Layout and Colors: User-configurable.
-
Controls: Capacitive Touch Screen and Trim Knob control and hard keys (standard).
-
ECG:
-
Leads Available:
-
3-Lead Configuration: I, II, III.
-
5-Lead Configuration: I, II, III, aVR, aVL, aVF, and V.
-
Sweep Speed: 12.5, 25, or 50 mm/s.
-
Gain Range: 0.5 x , 1 x, 2 x, and 4 x.
-
Heart Rate Accuracy: 30 to 300 bpm, +/- 5% or +/-5 bpm, whichever is greater.
-
50/60 Hz Power Supply:
-
Monitor: 0.5 to 40 Hz.
-
ST: 0.05 to 40 Hz.
-
Diagnostic: 0.05 to 145 Hz.
-
Pacemaker Detection:
-
Range: 2 to 700 mV.
-
Pulse Width: 0.5 to 2 ms.
-
Arrhythmia Analysis: Asystole, V Fib / V Tach, V Tach, VT>2 R on T, V Brady, Couplet, Bigeminy, Accelerated Ventricular arrhythmia, Multifocal PVCs, A Fib, Missing beat, Pause, Tachy, Brady, Trigeminy.
-
ST Segment Analysis:
-
Numeric Range: -9 to +9 mm (-0.9 to +0.9 mV).
-
Accuracy: +/- 0.2 mm or +/- 10%, whichever is greater, within the measurement range of -8 to 8 mm.
-
Numeric Resolution: 0.1 mm (0.01 mV).
-
ST Trends: Up to 168h.
-
Range:
-
Adult/Pediatric: 4 to 120 resp/min.
-
Neonate: 4 to 180 resp/min.
-
Accuracy: +/- 5% or +/- 5 resp/min, whichever is greater.
-
Gain Range: 0.1 to 5 cm/Ohm.
-
SpO2:
-
GE:
-
Pulse Oximetry Measurement Range: 1 to 100%.
-
Pulse Rate: 30 to 250 bpm.
-
Saturation Measurement Accuracy:
-
Without Motion-Adult/Pediatric Finger Sensor: 70 to 100% +/- 2%
-
Without Motion-Neonate: 70 to 100% +/- 3%.
-
With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
-
Low Perfusion-Adult/Pediatric: 70 to 100% +/-3% (1~69% unspecified).
-
Pulse Rate: Without Motion: +/- 2 bpm (adult/pediatric/neonatal).
-
Nellcor:
-
Pulse Oximetry Measurement Range: 1 to 100%.
-
Pulse Rate: 20 to 250 bpm.
-
Saturation Measurement Accuracy:
-
Adult: 70 to 100% +/- 2%.
-
Neo: 70 to 100% +/- 3%.
-
Low Perfusion: 70 to 100% +/- 2%; 0~69% unspecified.
-
Pulse Rate: +/- 3 bpm.
-
Masimo:
-
Pulse Oximetry Measurement Range: 1 to 100%.
-
Pulse Rate: 25 to 240 bpm.
-
Saturation Measurement Accuracy:
-
Without Motion-Adult/Pediatric: 70 to 100% +/- 2%.
-
Without Motion-Neonate: 70 to 100% +/- 3%.
-
With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
-
Low Perfusion: 70 to 100% +/-2% (0 to 69% unspecified).
-
Pulse Rate:
-
Without Motion: +/- bpm.
-
With Motion: +/- 5 bpm.
-
NIBP:
-
Measurement Technique: Oscillometric with step deflation.
-
Modes: Manual, Automatic, Stat.
-
Systolic Measurement Range:
-
Adult/Pediatric: 30 to 290 mmHg.
-
Neonate: 30 to 260 mmHg.
-
MAP Measurement Range:
-
Adult/Pediatric: 20 to 260 mmHg.
-
Neonate: 20 to 125 mmHg.
-
Diastolic Measurement Range:
-
Adult/Pediatric: 10 to 220 mmHg.
-
Neonate: 10 to 110 mmHg.
-
Accuracy: Meets AAMI ISO81060-2 and IEC 80601-2-30.
-
Default Initial Inflation Pressure:
-
Adult/Pediatric: 135 +/- 15 mmHg.
-
Neonate: 100 +/- 15 mmHg.
-
Maximum Determination Time:
-
Adult/Pediatric: 2 min.
-
Neonate: 100 +/- 15 mmHg.
-
Over Pressure Monitor:
-
Adult/Pediatric: 294 +/-6 to 330 mmHg.
-
Neonate: 147 +/- 3 to 165 mmHg.
-
Invasive Blood Pressure:
-
Measurement Range: -40 to 320 mmHg (15.3 to 42.7 kPa).
-
Measurement Accuracy; +/- 5% or +/- 2 mmHg, whichever is greater.
-
Frequency Response: 4 to 22 Hz.
-
Transducer Sensitivity: 5 ╬╝V/V/mmHg.
-
Temperature:
-
Numerical Display: T1, T2, T2-T1.
-
Measurement Range: 10 to 45 degrees C (50 to 113 degrees F).
-
Measurement Accuracy: +/- 0.1 degrees C without probe.
-
Display Resolution: 0.1 degrees C.
-
Probe: YSI probes recommended by GE Healthcare.
-
Networking:
-
Compatibility: CARESCAPE Network.
-
Wi-Fi Connectivity: IEEE 802.11a/b/g/n.
-
Wi-Fi Security:
- WPA-Personal.
- WPA2-Personal.
- WPA-Enterprise.
- WPA2-Enterprise.
Configurations
GE B125 Patient Monitor Configurations
-
#MFI-GEH-2099000-002-564816:Certified Refurbished: Masimo SpO2.
-
#2099000-002-565667: Factory New: GE Ohmeda SpO2.
-
#2099000-002-564816: Factory New: Masimo SpO2.
-
#2099000-002-565376: Factory New: Nellcor SpO2.
-
#2099000-002-565664: Factory New: GE Ohmeda SpO2, IBP (Invasive Accessories Not Included).
-
#2099000-002-565668: Factory New: Nellcor SpO2, IBP (Invasive Accessories Not Included).
-
#2099000-002-597226: Factory New: Masimo SpO2, Full Arrhythmia License (Invasive Accessories Not Included).
-
#2099000-002-565666: Factory New: Masimo SpO2, IBP (Invasive Accessories Not Included).
-
#2099000-002-586307: Factory New: Masimo SpO2, IBP, Full Arrhythmia License (Invasive Accessories Not Included).
Literature
GE B125 Patient Monitor Literature
GE B125 Patient Monitor Brochure
Customer Reviews 0 out of 5 - (Total 0 ratings)