The Bovie Smoke Shark II Smoke Evacuator includes a long life 35-hour Filter (#SF35), Pneumatic Footswitch (#FSSEP), User's Guide, and Power Cord.
Warranty: 2 Years - Limited Free from Defects in Material or Workmanship.
The Smoke Shark II minimizes exposure to toxic smoke plumes and aerosols during electrosurgery, laser, and harmonic scalpel procedures. This surgical smoke has been proven to carry viruses, CO, and other chemical and biological hazards.
It has been designed with a high suction, high flow rate vacuum motor. The ultra-quiet motor is used to draw the surgical smoke from the surgical site through the vacuum tubing and into the SF35 Filter where the surgical smoke is processed by a series of filters.
A single disposable filter is used to simplify the installation and removal during filter changes. The filter is completely enclosed to protect the healthcare personnel from potential contamination during filter changes.
Features
Bovie Smoke Shark II Smoke Evacuator Features
- A modern, light-weight, compact design allowing for simplified use, storage, and stack-ability.
- Never again order the Smoke Shark and still need to order a filter upon receipt.
- The SF35 Extended-Life Filter offers up to 35 hours of performance, reducing procedure cost by 38% (+/-) from the previous model, when used at the lowest setting.
- Compatible with most electrosurgical generators.
- Covered 3-port filter design accommodates a variety of tubing sizes [1/4" (6.4 mm), 3/8" (9.5 mm), and 7/8" (22 mm)] providing versatility in procedure and accessory setup.
- The ultra-quiet design offers the same excellent performance with less noise.
- The SE02 Smoke Shark is -3 and RoHS compliant.
- Excellent particle capture.
Typical Setups
Bovie Smoke Shark II Smoke Evacuator Typical Setups
-
Electrosurgery / Laser:
- Smoke Shark Unit with Pneumatic Footswitch (#FSSEP).
- Long Life 35-Hour Filter (#SF35).
- *7/8" x 6' Tube (#786T / Case of 24) or *7/8" x 6' Tube with Wand (#SETW / Case of 24).
- *Arm Stand (#SEAS).
-
OBGYN:
- Smoke Shark Unit with Pneumatic Footswitch (#FSSEP).
- Long Life 35-Hour Filter (#SF35).
- *7/8" x 6' Tube (#786T / Case of 24) or *7/8" x 6' Tube with Wand (#SETW / Case of 24).
*Items sold separately.
Specifications
Bovie Smoke Shark II Smoke Evacuator Specifications
-
Line Voltage:
- #SE02: 100/120 VAC.
- #SE02-220: 220/240 VAC.
-
Line Frequency: 50 - 60 Hz (auto sensed).
-
Dimensions and Weight:
- Width: 11" (27.9 cm).
- Height: 6" (15.2 cm).
- Depth: 15.5" (39.4 cm).
- Weight: 10 lb (4.3 kg).
-
Noise Level: 55 dBA (maximum).
Literature
Bovie Smoke Shark II Smoke Evacuator Literature
Bovie OBGYN Product Suite Brochure
Bovie Smoke Shark II Smoke Evacuator Brochure
Bovie Smoke Shark II Smoke Evacuator Operator's Manual
Customer Reviews 0 out of 5 - (Total 0 ratings)