The Allied Healthcare AutoVent 2000 Automatic Transport Ventilator is designed expressly for the EMS professional, providing independent controls for tidal volume and BPM. It is designed to meet ventilator needs in a variety of applications, from intra- and inter-hospital transports to sophisticated air rescue. Automatic transport ventilators have been recommended by the American Hospital Association as the preferred equipment to provide ventilator support in the pre-hospital setting.
Note: Oxygen source is not included.
Warranty: 1 Year - Free from Material Defects in Material and Workmanship.
The AutoVent 2000 uses state-of-the-art pneumatics to assure reliable, time-cycled constant flow ventilation powered by a minimum of source gas. It may be used with all models of the LSP single patient use ventilation circuits as an added protection against patient cross-contamination.
The AutoVent 2000 Automatic Transport Ventilator is accompanied by the proven LSP patient valve with its bright green visual breath indicator, built-in audible pressure limit alarm, and intermittent mandatory ventilation providing gas flow for spontaneous breathing patients. The patient valve is available with an anti-inhalation valve for use in toxic environments.
Features
Allied Healthcare AutoVent 2000 Automatic Transport Ventilator Features
- Small, compact, and transport ready.
- Designed to perform in harsh and toxic environments.
- Assembles quickly with simplified operating instructions printed on the case.
- Impact-resistant case with shock-absorbing bumpers and recessed control settings.
- Rate and volume settings independently operated.
- Easy-to-monitor patient valve assembly and toxic atmosphere valve are able to deliver additional breaths on demand by inspiratory effort of the patient.
- Operates exclusively on standard 50 psi source gas, eliminating air entrainment and maintaining the integrity of the specified oxygen concentration.
- Operates at extreme temperatures.
- No batteries needed; pneumatically-powered.
- Allows for PEEP attachment.
- Meets ASTM, ISO, and KKK-1822C standards.
Specifications
Allied Healthcare AutoVent 2000 Automatic Transport Ventilator Specifications
-
Supply Pressure Range: 40 - 60 psig.
-
Gas Consumption Driving Gas: 0.5 lpm maximum.
-
Operating Temperature: 0 to 125 ┬░F.
-
Storage Temperature: -40 to 160 ┬░F.
-
Shipping Dimensions: 15" x 12" x 9" (38 cm x 30.5 cm x 23 cm).
Control Module:
-
Weight: 24 oz. (680 grams).
-
Dimensions: 1.75" (D) x 6" (W) x 3.5" (H) (4.4 cm x 15.24 cm x 8.9 cm).
-
Frequency: 8 to 20 BPM.
-
Tidal Volume: 400 to 1200 ml.
-
Flow Rate: 16 to 48 lpm.
-
Inspiratory Time: Approx. 1.5 or 2.0 seconds.
-
Expiratory Time: 1.5 to 6.0 seconds.
-
I-E Ratio: 1:1 to 1:4.
-
Case Material: Polyester.
-
Input Connection: Plated brass.
-
Output Connection: Plated brass.
-
Minute Volume: 0 to 24 lpm.
-
Driving Gas: 0.5 lpm maximum.
Patient Valve Assembly:
-
Weight: 16 oz. (450 g).
-
Flow: 0 - 48 lpm at 50 psig (as required in demand mode).
-
Peak Inspiratory Flow: 48 lpm at an airway pressure drop of less than 2.5 cm H2O.
-
Delivery Pressure: 60 +/- 5 cm H2O.
-
(Insp.) Crack Pressure: 0 to -2 cm H2O (0 to -0.8" H2O).
- Exhalation Resistance:
- 0 - 10 lpm: 1.5 cm H2O (max).
- 11 - 70 lpm: 3.8 cm H2O (max).
-
Dead Space: 8 ml (excluding mask).
-
Inlet Fitting: Standard male oxygen DISS.
-
Filter: 25 micron stainless steel mesh.
-
Outlet: 22 mm outside diameter x 15 mm inside diameter (fits standard medical masks, endotracheal tubes, and tracheostomy tubes).
-
Materials:
- Body - anodized aluminum.
- Cover - polycarbonate.
- Outlet fitting - polycarbonate.
- Inlet fitting - plated brass.
Configurations
Allied Healthcare AutoVent 2000 Automatic Transport Ventilator Configurations
MPN |
Condition |
Inspiratory Time |
Included Accessories |
Shipping Weight |
#LSPAV2K |
Certified Refurbished |
- |
Control Module, twin hose, 6' O2 hose, patient valve, adult circuit, and manual |
- |
#L460 |
Factory New |
2 seconds |
Control Module, patient valve, supply tubing, 6' O2 hose, and non-rebreathing valve with hose |
5.7 lb (2.59 kg) |
#L460-150 |
Factory New |
1.5 seconds |
Control Module, patient valve, supply tubing, 6' O2 hose, and non-rebreathing valve with hose |
5.75 lb (2.6 kg) |
Accessories
Allied Healthcare AutoVent 2000 Automatic Transport Ventilator Accessories
The following accessories are compatible and commonly purchased with the AutoVent 2000 Automatic Transport Ventilator:
-
#L270-220: Oxygen Regulator, CGA 870, 0 - 25 lpm, with gauge, 2 check valves, and hose barb outlet.
-
#L280-220: Oxygen Regulator, CGA 540, 0 - 25 lpm, with gauge, 2 check valves, and hose barb outlet.
-
#L599-010: Ventilation Circuit, single patient use, with patient valve, corrugated tubing (10/Case)
-
#L599-030: Ventilation Circuit, single patient use, with patient valve, corrugated tubing, swivel connector (10/Case).
-
#L599-090: Ventilation Circuit, single patient use, with patient valve, corrugated tubing, swivel connector, exhalation filter (10/Case).
-
#L535026: Oxygen Hose, 6', DISS fittings.
-
#L535114: Oxygen Hose Assembly.
Literature
Allied Healthcare AutoVent 2000 Automatic Transport Ventilator Literature
Allied Healthcare AutoVent 2000 / 3000 Brochure
Customer Reviews 0 out of 5 - (Total 0 ratings)